KnowledgeECONOMICS
CONTACT US
Hunan Perfect Industry Co.,Ltd
Contact: Manager Hu, Manager Yi
Hotline:008618507312158
Cell phone:008613974960765
Address:Xiangyin County Industrial Park, Yueyang City, Hunan Province, China
Current location: HOME »Knowledge »Vertical Sump Pump
Faults, Causes and Solutions of Multi-sucker Corrosion Resistant Subaqueous Sewage sump Pump
1. Flow or head of multi-sucker anti-corrosive submerged sewage sump pump can not meet the requirements.
NO | Cause analysis | Resolvent |
1 | Pump reversal | Turn off the main power supply of the control box and replace any two-phase power cord |
2 | Head is too high | Check: A. Is the pump type selected correct? B. Is the size of the outlet pipe correct? |
3 | Delivery medium to bypass | Check whether bypass valve is closed and then test pump with full load |
4 | Leakage of Outlet Pipeline | Find the leak and solve it. |
5 | Local outlet pipeline may be blocked by deposited oxides | Check pipelines, clean and replace new ones |
6 | Local Blockage of Pump | Lifting pump cleaning, if the pump is placed in the package filter, also need to be checked and cleaned. |
7 | Too much wear on impeller and sealing ring | Replacement of impeller and sealing ring |
2. No flow rate after operation of multi-sucker corrosion-resistant submerged sewage pump
NO | Cause analysis | Resolvent |
1 | Air plug | A. Open and close the valve several times continuously. B. Start/stop the pump several times, and the interval between each restart is not less than 10 minutes. |
2 | Inspection of effluent discharge valve | According to different installation methods: A. Check whether an air release valve is required. B. If the valve is closed, it should be opened. |
3 | Pump reversal | Turn off the main power supply of the control box and replace any two-phase power cord. |
3. Start-up and stop of multi-suction anti-corrosive submerged sewage sump pump too frequently
NO | Cause analysis | Resolvent |
1 | Floating Ball Switch (or Level Meter) Setting Time Too Short | Re-adjust float switch (or level gauge) to prolong operation time |
2 | Check valve failure, the check valve can not be checked, so that the liquid back into the sewage tank | Inspect and maintenan |
4. Multi-suction anti-corrosive submerged sewage pump can not start, fuse fuse or circuit breaker jump off
NO | Cause analysis | Resolvent |
1 | Relay failure | Repair or replace |
2 | Fault of float switch (or level gauge) | Check whether the float switch (or level gauge) can start the pump. If not, check the float switch (or level gauge). |
3 | Winding, joint or cable break | Check with the OM table. If it turns out to be a circuit breaker, check the windings, terminals and cables. |
4 | Pump blocked | Cut off the power supply, remove the pump from the sewage tank and remove obstacles. |
5 | Leakage or leak blockade | Find out the cause and troubleshoot. |
5. The multi-sucker anti-corrosive sewage pump can not start, but the fuse is not broken or the overload protector does not jump off.
NO | Cause analysis | Resolvent |
1 | No electricity | A. Check whether the control box is electrified. B. Check the control box carefully for any faults. |
2 | Breaking of windings, cables, wiring heads or control boxes | Check the connection and winding of cable and motor. |
6. Stop Failure of Multi-sucker Corrosion Resistant Subaqueous Sewage Pump
NO | Cause analysis | Resolvent |
1 | Floating Ball Switch (or Level Meter) "Stop" Function Failure | Check whether the float switch (or level gauge) can stop the pump. If not, check the float switch (or level gauge). |
2 | The float switch (or level gauge) is always in the "working" state. | Inspect and maintenan |
7. The circuit breaker/overloader jumps off after the start-up of the multi-suction anti-corrosive submerged sewage sump pump
NO | Cause analysis | Resolvent |
1 | Low Voltage | A. Check the voltage of the control box. If the voltage is too low, it can not be used temporarily. B. If the cable is too long and the voltage drop is too large, the cable should be shortened as far as possible and the coarser cable should be selected appropriately. |
2 | Overvoltage | Install transformer to adjust voltage to specified range. |
3 | Incorrect connection of motor or confusion of connection | Check the cable color number and wiring head label in the control box, and check the wiring. |
4 | short circuit | Find out the cause and troubleshoot |
5 | Control box or capacitor failure | A. Check the control box carefully and forbid replacing the circuit breaker with components that exceed the recommended value. B. If the control box fails, it should be repaired or replaced. |
6 | Mud or other sediments accumulated in the sewage tank | Clean up the sewage tank of the pump. See the relevant parts of the installation instructions. |
8. Vibration of multi-sucker anti-corrosive submerged sewage sump pump unit with murmur and abnormal operation
NO | Cause analysis | Resolvent |
1 | Bearing wear | Replacement of bearings |
2 | Rotor unbalance | Check the reason, balance and fix the bolts of each part. |
3 | Installation system foundation strength is insufficient or pump installation is uneven | Reinforcing the foundation and leveling the pump. |
4 | Bending of Rotary Shaft | Send factory correction or replacement. |